China Factory · Bulk Export Supply OEM / ODM FOB · CIF · FCL · Mixed Container

Metric height 1800 mm | Line wires 15–18 | Construction Hinge joint

KUNYU FENCING

1.8m Hinge Joint Fence

An 1800 mm hinge joint fence with four published layouts for taller agricultural boundaries. Compare 15–18 horizontal line wires without changing the specified fence height.

1800 mm height4 mesh layoutsWholesale & OEM

Mesh layout: 16-1800 [A-015]

Request This ConfigurationDiscuss Specifications on WhatsApp

Your selected layout is included in the quote request. Add quantity and destination in the form.

One height · several mesh choices

1800 mm Hinge Joint Fence Specifications

The 18-wire option uses two 150 mm and fifteen 100 mm openings. The 15-wire option uses three 200 mm, two 150 mm and nine 100 mm openings. This makes wire density and opening size easy to compare within one height.

Layout / referenceHeightLine wiresVertical opening scheduleSelect
18-1800
A-013
1800 mm182 × 150 + 15 × 100 mm
17-1800
A-014
1800 mm171 × 200 + 2 × 150 + 13 × 100 mm
16-1800
A-015
1800 mm162 × 200 + 2 × 150 + 11 × 100 mm
15-1800
A-016
1800 mm153 × 200 + 2 × 150 + 9 × 100 mm

The opening schedule lists gaps between horizontal line wires. Stay spacing is the horizontal distance between vertical wires. Different records can share a two-part layout code; include the reference in your RFQ.

Choose the Wire, Coating and Packing

The mesh code identifies the layout. These choices complete the specification for pricing and production.

Wire diameters, tensile options and zinc coating

Wire & mesh choices

ConstructionHinge joint woven wire
Stay spacing50 mm increments, starting at 50 mm; specify the ordered dimension
Edge wire diameter1.8–3.2 mm; at least as thick as inner wires
Inner wire diameter1.8–2.5 mm; line and stay values specified separately
Diameter tolerance−0.05 to 0.00 mm against the selected nominal diameter
Wire tensile options450 ± 50, 550 ± 50 or 1000 ± 50 MPa; confirm the line/stay combination
Roll lengthSpecify the required length in your RFQ

Coating & wholesale supply

Zinc option / MOQ40 ± 10 g/m² / 3 tonnes
Zinc option / MOQ200 ± 20 g/m² / 8 tonnes
PackingRoll labels, pallet arrangement and protection agreed per order
Mixed modelsAsk sales to review the mix against the minimum order and packing plan
Price & lead timeQuoted against the complete specification, quantity and destination
Roll weightCalculated for the chosen wire, stay spacing and roll length
DocumentsState the inspection and test documentation required with your RFQ

Tensile values describe wire choices, not the breaking load of a finished fence. Specify the applicable product standard and coating test requirements separately; zinc mass alone does not establish a coating class or guarantee service life.

What your quotation and inspection plan should cover
  • Approved height, line-wire count and opening schedule, with order drawing.
  • Separate edge, line and stay wire diameters and tensile requirements.
  • Zinc mass, applicable test requirements and requested documentation.
  • Roll length, roll weight, labels, packing arrangement and destination port.

Ask for sample and batch inspection arrangements with your quotation. Timing and documentation are agreed for the order.

Taller agricultural boundaries and orchard perimeter review

Check the complete fence system

For orchard or woodland projects, review wildlife pressure, the ground interface and the complete fence system. This page does not imply a guaranteed deer-containment height.

Read the field fence installation guide

Keep metric and imperial sizes separate

1800 mm is approximately 70.87 in; a 6 ft fence is 1828.8 mm. Keep these heights separate in drawings and purchase orders.

Read the fence size and model guide

Buyer Questions

What does 16-1800 mean?

It identifies 16 horizontal line wires and a 1800 mm height. The reference A-015 identifies the opening schedule. Stay spacing, wire specification, coating and roll length are specified separately.

How do I compare layouts at this height?

The 18-wire option uses two 150 mm and fifteen 100 mm openings. The 15-wire option uses three 200 mm, two 150 mm and nine 100 mm openings. This makes wire density and opening size easy to compare within one height.

Is 150 mm stay spacing the same as 6 inches?

No. Six inches is 152.4 mm. Specify the actual spacing and tolerance required instead of treating an imperial model and a metric layout as interchangeable.

What roll length and quantity should I request?

Enter your required roll length and total quantity. The factory quotation confirms the length, roll weight, packing and lead time for the selected construction.

What is the minimum order?

The metric range has a 3 tonne minimum for 40 ± 10 g/m² zinc and an 8 tonne minimum for 200 ± 20 g/m² zinc. Ask sales to review mixed-layout eligibility for your order.

What should a quotation include?

Layout reference, height, stay spacing, edge/line/stay wire diameters, tensile combination, zinc mass, roll length, quantity, labels, packing and destination port.

Compare Nearby Heights

Specification information updated 2026-09-23. KUNYU FENCING · Zhejiang Kunyu Wiremesh Co., Ltd.