China Factory · Bulk Export Supply OEM / ODM FOB · CIF · FCL · Mixed Container

Metric height 2000 mm | Line wires 17–19 | Construction Hinge joint

KUNYU FENCING

2m Hinge Joint Deer & Field Fence

A 2000 mm hinge joint woven-wire range for tall field-fence and deer-fence specification reviews. Three layouts provide 17, 18 or 19 horizontal line wires at the same metric height.

2000 mm height3 mesh layoutsWholesale & OEM

Mesh layout: 18-2000 [A-008]

Request This ConfigurationDiscuss Specifications on WhatsApp

Your selected layout is included in the quote request. Add quantity and destination in the form.

One height · several mesh choices

2000 mm Hinge Joint Fence Specifications

The 18-2000 layout has two 200 mm, two 150 mm and thirteen 100 mm openings. Compare the 17- and 19-wire options when balancing mesh opening size, wire content and the project specification.

Layout / referenceHeightLine wiresVertical opening scheduleSelect
19-2000
A-007
2000 mm191 × 200 + 2 × 150 + 15 × 100 mm
18-2000
A-008
2000 mm182 × 200 + 2 × 150 + 13 × 100 mm
17-2000
A-009
2000 mm173 × 200 + 2 × 150 + 11 × 100 mm

The opening schedule lists gaps between horizontal line wires. Stay spacing is the horizontal distance between vertical wires. Different records can share a two-part layout code; include the reference in your RFQ.

Choose the Wire, Coating and Packing

The mesh code identifies the layout. These choices complete the specification for pricing and production.

Wire diameters, tensile options and zinc coating

Wire & mesh choices

ConstructionHinge joint woven wire
Stay spacing50 mm increments, starting at 50 mm; specify the ordered dimension
Edge wire diameter1.8–3.2 mm; at least as thick as inner wires
Inner wire diameter1.8–2.5 mm; line and stay values specified separately
Diameter tolerance−0.05 to 0.00 mm against the selected nominal diameter
Wire tensile options450 ± 50, 550 ± 50 or 1000 ± 50 MPa; confirm the line/stay combination
Roll lengthSpecify the required length in your RFQ

Coating & wholesale supply

Zinc option / MOQ40 ± 10 g/m² / 3 tonnes
Zinc option / MOQ200 ± 20 g/m² / 8 tonnes
PackingRoll labels, pallet arrangement and protection agreed per order
Mixed modelsAsk sales to review the mix against the minimum order and packing plan
Price & lead timeQuoted against the complete specification, quantity and destination
Roll weightCalculated for the chosen wire, stay spacing and roll length
DocumentsState the inspection and test documentation required with your RFQ

Tensile values describe wire choices, not the breaking load of a finished fence. Specify the applicable product standard and coating test requirements separately; zinc mass alone does not establish a coating class or guarantee service life.

What your quotation and inspection plan should cover
  • Approved height, line-wire count and opening schedule, with order drawing.
  • Separate edge, line and stay wire diameters and tensile requirements.
  • Zinc mass, applicable test requirements and requested documentation.
  • Roll length, roll weight, labels, packing arrangement and destination port.

Ask for sample and batch inspection arrangements with your quotation. Timing and documentation are agreed for the order.

Deer, orchard and woodland boundary specification review

Check the complete fence system

Deer and wildlife behavior varies. Confirm the required height, opening pattern, post-and-brace design and site conditions with a qualified installer; this product name is not a containment guarantee.

Read the field fence installation guide

Keep metric and imperial sizes separate

This 2000 mm range uses 17–19 line wires. The separate 1478-6-330 model has 14 wires and a nominal 78 in / 1981 mm height, so it is not an equivalent SKU.

Read the fence size and model guide

Buyer Questions

What does 18-2000 mean?

It identifies 18 horizontal line wires and a 2000 mm height. The reference A-008 identifies the opening schedule. Stay spacing, wire specification, coating and roll length are specified separately.

How do I compare layouts at this height?

The 18-2000 layout has two 200 mm, two 150 mm and thirteen 100 mm openings. Compare the 17- and 19-wire options when balancing mesh opening size, wire content and the project specification.

Is 150 mm stay spacing the same as 6 inches?

No. Six inches is 152.4 mm. Specify the actual spacing and tolerance required instead of treating an imperial model and a metric layout as interchangeable.

What roll length and quantity should I request?

Enter your required roll length and total quantity. The factory quotation confirms the length, roll weight, packing and lead time for the selected construction.

What is the minimum order?

The metric range has a 3 tonne minimum for 40 ± 10 g/m² zinc and an 8 tonne minimum for 200 ± 20 g/m² zinc. Ask sales to review mixed-layout eligibility for your order.

What should a quotation include?

Layout reference, height, stay spacing, edge/line/stay wire diameters, tensile combination, zinc mass, roll length, quantity, labels, packing and destination port.

Compare Nearby Heights

Specification information updated 2026-09-23. KUNYU FENCING · Zhejiang Kunyu Wiremesh Co., Ltd.